Com-Tech 200/400/800/1600 Power Amplifiers
140 volt distributed loudspeaker systems. If you will be
using 140 volt output, you may need to cross-refer-
ence the ratings of the step-down transformer taps
with Crown’s constant voltage computer (see Section
8.3). If you need a single channel with higher power to
drive a 70 volt line, use Parallel-Mono mode.
WARNING: Both channels must be configured for the
same output mode (8/4 ohm or 70 volt) before switch-
ing to Bridge-Mono mode.
Bridge-Mono wiring is very different from the other
modes and requires special attention. First, turn the
amplifier off. Then select Bridge-Mono mode by sliding
the dual/mono switch to the right (as you face the back
panel). Both outputs will receive the signal from chan-
nel 1 with the output of channel 2 inverted so it can be
bridged with the channel 1 output. DO NOT USE THE
CHANNEL 2 INPUT or the signal level and quality may
be greatly degraded. Also, keep the channel 2 level
control turned down completely (counterclockwise).
Note: The channel 2 input jack and level control are not
defeated in Bridge-Mono mode. A signal feeding
channel 2 will work against the channel 1 signal, and
usually results in distortion and inefficient operation.
Connect the load across the two positive (+) output ter-
channel can be used to drive a 70 volt line. Installation
is intuitive: input channel 1 feeds output channel 1,
and input channel 2 feeds output channel 2.
To put the amplifier into Dual mode, turn it off, slide the
dual/mono switch to the center position, and properly
connect the output wiring. Be sure to observe correct
loudspeaker polarity (see Figure 3.4) and be careful
not to short the two outputs.
CAUTION: Never tie an amplifiers outputs together di-
rectly, and never parallel them with the output of an-
other amplifier. Such connections do not result in
increased output power, but may cause overheating
and premature activation of the protection circuitry.
Note: To parallel multiple amplifiers for fail-safe redun-
dancy, contact Crown’s Technical Support Group.
BRIDGE
MONO
DUAL
PARALLEL
MONO
B R I D G E - M O N O
Bridge-Mono mode is used to drive loads with a total
impedance of at least 4 ohms (see
Parallel-Mono
if the
load is less than 4 ohms). If Bridge-Mono mode and
70 volt output are used together, twice the normal out-
put voltage is produced from a single channel to drive
Use Dual 70 volt mode
for Fire Protective Sig-
naling applications (see
Section 9).
Fig. 3.5 Wiring for Dual 70 Volt Mode
+
COM
+
COM
+
+
70 VOLT STEP-DOWN
TRANSFORMERS
16, 8, OR 4 OHM
16, 8, OR 4 OHM
70 VOLT LINE
MIXER
LOUDSPEAKERS
Com-Tech Amplifier
CHANNEL 1
CHANNEL 2
CHANNEL 1
CHANNEL 2
DUAL 70 VOLT MODE
(BOTH CHANNELS)
TURN OFF THE AMPLIFIER
BEFORE CHANGING
THE DUAL/MONO SWITCH.
TURN OFF THE AMPLIFIER
BEFORE CHANGING THE
OUTPUT MODE SWITCHES.
70
VOLT
70
VOLT
8/4
OHM
8/4
OHM
CH1
CH2
BRIDGE
MONO
DUAL
PARALLEL
MONO
BB
Programmable
Input Processor (P.I.P.)
+
CH-2 INPUT
+
CH-1 INPUT
P
R
E
S
S
R
E
S
E
T
PUSH TO RESET
CH-2 CH-1
0
dB
.5
1
2
3
4
5
6
7
8
910
11
13
15
17
19
21
25
32
0
dB
.5
1
2
3
4
5
6
7
8
910
11
13
15
17
19
21
25
32
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 48 49

Comments to this Manuals

No comments