Crown IQ-MC8 User Manual

Browse online or download User Manual for Telephones Crown IQ-MC8. CTs 8200 - LydRommet

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
CTs 8200
CTs SERIES
B
uilding on the foundation of the
Com-Tech
®
Series, Crown’s CTs Series
offers new fl exibility and value for
installed sound applications. The Com-Tech
Series were the fi rst to offer independent selec-
tion of high- and low-impedance operation for
a specifi c channel, and CTs Series amplifi ers
continue that tradition, with power levels and
features carefully chosen to perfectly integrate
into fi xed install design requirements. For
added fl exibility, the CTs Series includes both
dual-channel and multi-channel models.
All models in the CTs Series feature Crown’s
new Switching Power Supply for lighter weight,
and all models are also compatible with the
IQ System
®
. Multi-channel models accept new
MC accessory modules that provide enhanced
control, monitoring, and system integration.
In a profession where unplanned service calls
quickly wipe out profi ts, the CTs Series ampli-
ers are designed to be the most reliable ampli-
ers you can install.
For more details about the Crown CTs
Series, contact Crown Customer Service at
800-342-6939 or 574-294-8200. Also, visit the
Crown Audio website at www.crownaudio.com.
Specifi cations
Minimum Guaranteed Power
Frequency Response (at 1 watt, 20 Hz - 20
kHz): ±0.5 dB.
Phase Response (at 1 watt, 10 Hz - 20 kHz):
±35°.
Signal to Noise Ratio below rated power (20
Hz to 20 kHz): 100 dB unweighted.
Total Harmonic Distortion (THD) at 1 watt,
from 20 Hz to 20 kHz: < 0.05%.
Intermodulation Distortion (IMD) 60 Hz and
7 kHz at 4:1, from 163 milliwatts to full band-
width power: < 0.05% (typical).
Damping Factor: 10 Hz to 400 Hz: >180.
Crosstalk (below rated power, 20 Hz to 1 kHz):
> 80 dB.
Common Mode Rejection (CMR) (20 Hz to 1
kHz): > 50 dB.
DC Output Offset (Shorted input): < 5 mV.
Input Impedance (nominal): 20 kilohms bal-
anced, 10 kilohms unbalanced.
Maximum Input Level (before input compres-
sion): + 20 dBu.
Load Impedance (Note: Safe with all types of
loads),
Stereo: 4/8 and 25 ohms (70V);
Bridge Mono: 8/16 and 50 ohms (100V
Voltage Gain (at maximum level setting), 1.4V
sensitivity,
4/8 Ohm Operation: 20:1 (26 dB);
70V Operation: 50:1 (34 dB)
100V Operation: 71.4:1 (37 dB)
Required AC Mains: 120V 60 Hz, 220/230/
240V/50 Hz.
Power Draw at Idle (120VAC mains, all chan-
nels in 4/8 ohm mode): 70W;
Power Draw at Idle (120VAC mains, all chan-
nels in 70V mode):114W.
Cooling: Continuously variable speed forced air,
front-to-back airfl ow.
Dimensions: Width, Height, Depth: 19 in. (48.3
cm) W x 5.25 in. (13.3 cm) H x 16.25 in. (41.3
cm) D.
Weight,
Net: 36 lb 6 oz (16.5 kg);
Shipping: 47 lb (21.3 kg).
Front Panel Controls and Indicators
Bridge Mode Indicator: Yellow LED, one per
channel pair, illuminates when the channel
pair’s Mode Switch is set to the “Bridge” posi-
tion. If Mode switch is changed while amplifi er
is powered up, Bridge LED will fl ash, indicating
that the amplifi er must be powered off and on
to reset the Mode.
Features
New Crown Switching Power Supply for
reduced weight.
High power-density, with eight channels in a
3U chassis.
Selectable constant-voltage (70V/100V*) or
low-impedance (4/8 ohm) operation for each
channel pair.
FIT (Fault Isolation Topology) circuitry iso-
lates faults within affected channels.
TLC protection circuitry protects the ampli-
er from excessive heat by subtly and
dynamically reducing the gain only when
necessary to reduce heat levels.
JTS circuitry protects output transistors from
unsafe operating conditions without shutting
the channel down.
Accepts new MC accessory modules that
tailor the amplifi er to suit specifi c appli-
cations. Modules available for remote VCA
level control and IQ System
®
Control.
35-Hz High-Pass Filter is automatically
inserted when the channel pair is set
for constant-voltage operation (corner fre-
quency may be changed as a service
option).
Comprehensive array of indicators including
Power and Data, along with Bridge, Ready,
Signal, Clip, Thermal and Fault for each
channel, provide accurate diagnostics.
Blue Power Indicator fl ashes if the amplifi er
shuts off due to an under/over voltage condi-
tion on the AC mains.
Advanced protection circuitry guards against:
shorted outputs, open circuits, DC, mis-
matched loads, general overheating, under-
/over-voltage, high-frequency overloads and
internal faults.
Proven Crown AB+B Multi-Mode
®
output
topology.
Continuously-variable fans optimize cooling
effi ciency.
Three Year, No-Fault, Fully-Transferable
Warranty completely protects your invest-
ment and guarantees its specifi cations.
Crown’s advance-replacement Profi t Protec-
tion Plan provides quick, no-questions-asked
replacement of covered amps.
* Channel pair must be operated in Bridge mode for 100V output.
Page view 0
1 2

Summary of Contents

Page 1 - CTs 8200

CTs 8200CTs SERIESBuilding on the foundation of the Com-Tech® Series, Crown’s CTs Series offers new fl exibility and value for installed sound applicat

Page 2

Crown InternationalP.O. Box 1000Elkhart, IN 46515-1000TEL: 574-294-8200FAX: 574-294-8FAXwww.crownaudio.com10/02

Comments to this Manuals

No comments