Crown FMX250 User Manual Page 26

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 25
3–7Operation
3.3.5 RF power reading and selector switch
The Transmitter Controller has a digital panel meter which displays Forward RF 
Power and Reverse RF Power as detected by the RF power sampler attached to the 
end of the combiner. The reading on the display is determined by the setting of the 
selector switch and accompaning green LED indicator. The readings are in 
KiloWatts and have an accuracy of better that 2%. However, it is recommended that 
an external watt meter be used for a more accurate reading. See illustration 3-7 for 
the location of the panel meter and selector switch with accompaning green LED 
indicators.
Illustration 3-7 RF Power Reading and Selector Switch
Page view 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 43 44

Comments to this Manuals

No comments